指導教授

個人簡介

Name: Liang Yu Shyu
Office Address: Department of Biomedical Engineering, Chung Yuan 
Christian University Chung Li, Taiwan, 32023, R.O.C. 
Office Phone: (03) 2654515
       
University of Miami, FL, U.S.A. 
1986-1992    
Ph.D. in Biomedical Engineering    
Doctoral Dissertation: Systematic Investigation of Event Detection, Hardware, and Models for Impedance Cardiography.
University of Miami, FL, U.S.A.
1983-1985    
M.S. in Biomedical Engineering    
Master's Thesis: An Investigation of the Interaction of Aerobic Fitness, 
Physical Exercise and Emotional Stress on the Cardiovascular System, Using 
Microcomputer Based Instrumentation.
Chung Yung Christian University, Chung Li, Taiwan, Republic of China
1974-1978     
 B.S. in Biomedical Engineering 
專長
Signal processing: Spectral analysis, matched filtering, correlation 
analysis, coherent ensemble averaging,  adaptive filtering, active filter design and implementation,  digital filter design and implementation, wavelet analysis
Programming languages: FORTRAN, C, BASIC, Assembler, .
Animal experiments, surgery, catheter and flow probe implantation.
Image processing, digital signal processing chip.
經歷
服務機關
服務部門
職稱
起迄年月
Chung Yuan Christian University Department of Biomedical Engineering,   Department Head 1999-2001
Chung Yuan Christian University Department of Biomedical Engineering,   Associate Professor 1994 to date
American Heart Association   Research Fellow 1992-1993
University of Miami, FL  Department of Psychology, Behavioral Medicine 
Research Program
Research Assistant 1986-1992
University of Miami, FL Department of Psychology, Behavioral Medicine 
Research Program
Research Assistant 1983-1985 
Rotary Medical Instrument Inc. Taipei, Taiwan, Republic of 
China 
Maintenance Engineer 1981-1983
 期刊著作
  1. Shyu, L.Y., Hseih, Y.Y., Tai, C.T., Kao, T. and Hu, W.C. (2004) Methodology Improvement in Defining Characteristics of Atrial Fibrillation Termination, Computers in Cardiology, Vol. 31, 33- 35. (EI)
  2. Weng, C. S., Hung, Y. L., and Shyu, L.Y., (2004) A Study of Electrical Conductance of Meridian in the Obese During Weight Reduction, American J. of Chinese Medicine, Vol. 32, No. 3, 417-425. (SCI)
  3. Shyu, L.Y., Wu, Y.H. and Hu, W.C., (2004) Using Wavelet Transform And Fuzzy Neural Network for VPC Detection From the Holter ECG, IEEE Trans. Biomed. Eng, vol. 51, no. 7, 1269-1273.(SCI)
  4. Shyu, L.Y., Lin, Y.S., Liu, C.P. and Hu, W.C., (2004) The Detection of Impedance Cardiogram Characteristic Points Using Wavelet Transform, Computers in Biology and Medicine, vol. 34, 165-175.(SCI)
  5. Hu, W.C., Chen, J., Lai, F., Shyu, L.Y., Tai, C.T. and Kao, T., (2003) Evaluation of the Multiple Frequency Distribution of Conduction Block in Atrial Fibrillation, Computers in Cardiology, Vol. 30, 493-496. (EI)
  6. Shyu, L.Y., Chen, J.Y., Tatn, R.W. and Hu, W.C., (2002) A New Electrode System for Hand Action Discrimination, Journal of Medical and Biological Engineering, Vol. 22, No. 4, 211-217.
  7. Hu, W.C., Chang, S.H. and Shyu, L.Y., (2002) A Portable Signal Acquistion System Using Parallel Port of Personal Digital Assistant, Journal of Medical and Biological Engineering, Vol. 22(s), s69-s79.
  8. Hu, W.C., Wu, M.T., Liu, C.P., Shyu, L.Y. and Hsu, T.L., (2002) Left Ventricular 4D Echocardiogram Motion and Shape Analysis, Ultrasonics, 40, 949-954.(SCI)
  9. Tai, C. T., Chen, S. A., Tzeng, J. W., Kuo, B. I., Ding, Y. A., Chung, M. S. and Shyu, L. Y., (2001) Prolonged Fractionation of Paced Right Atrial Electrograms in Patients With Atrial Flutter and Fibrillation, Journal of the American College of Cardiology, Vol. 37, No. 6, 1651-1657.(SCI)
  10. Hu, W.C., Liu, S.F., Wu, M.T., Liu, C.P. and Shyu, L.Y., (2001) Left Ventricular Motion and Shape Analysis System, Journal of Medical and Biological Engineering, Vol. 21, No. 1, 31-42.
  11. Shyu, L.Y., Chiang, C.Y., Liu, C.P. and Hu, W.C., (2000) Portable Impedance Cardiography System for Real-time Noninvassive Cardiac Output Measurement, Journal of Medical and Biological Engineering, Vol. 20, No. 4, 193-202.
  12. Kao, T., Liu, A.S., Tai, C.T., Chen, S.A. and Shyu, L.Y., (2000) Frequency Analysis of Atrial Fibrillation Activity on The Surface Electrocardiogram, Chinese Journal of Medical and Biological Engineering, Vol. 20, No. 2, 77-82.
  13. Weng, C.S., Shyu, L.Y., Chang, Y.H. and Wu, J.X., (2000) Acoustic Signal Processing for Chinese Meridian System, Chinese Journal of Medical and Biological Engineering, Vol. 20, No. 1, 43-51.
  14. Liu, H.C., Li, C.Y. and Shyu, L.Y., (1999) Time-frequency Analysis of Heart Rate Variability During General Anesthesia at Different Time Induction, Chinese Journal of Medical and Biological Engineering, Vol. 19, No. 3, 193-202.
  15. Shyu, L.Y. (1998) The Development and Implementation of a Portable Fetal Electrocardiogram Monitoring System, Chung Yuan Journal, Vol. 26, N0. 3, 63-69.
  16. Weng, C.S., Shyu, L.Y., Chang, Y.H. and Chiang, L.N., (1998) A Study of Acoustical Method in Traditional Chinese Medicine for The Upper GI Disorder Patients, Chinese Journal of Medical and Biological Engineering, Vol. 18, No. 4, 245-251.
  17. Hu, W.C., Lai, C.Y., Shyu, L.Y. and Tung,C.S. (1998). A Methodological Improvement and System Validation to Obtain Precise Behavioral Parameters for Schedule-Induced Polydipsia. Chinese Journal of Physiology, 41(1): 9-17.
  18. Lai, C.Y., Lin, S.C., Shyu, L.Y., Tung, C.S. and Hu, W.C. (1997). Schedule-Induced Polydipsia Experimental Device Improvement for Acquiring and Quantitative Analysis of Animal Behavior, Chinese Journal of Medical and Biological Engineering, Vol. 17, No. 4, 241-248.
  19. Yang, M.Y., Shyu, L.Y., Hu, W.C., Chang, W.H. and Kao, T. (1997). Automatic ECG Classification Using Wavelet and Neural Networks”, Chinese Journal of Medical and Biological Engineering, Vol. 17, No. 4, 265-275
  20. Hurwitz, B.E., Shyu, L.Y., Lu. C.C., Reddy, S.P., Schneiderman, N., and 
    Nagel, J.H. (1993). Signal Fidelity Requirements For Deriving Impedance 
    Cardiographic Measures of Cardiac Function Over a Broad Heart Rate Range, Biological Psychology, 3-21.
  21. Nagel, J.H., Shyu, L.Y., Reddy, S.P., Hurwitz, B.E., McCabe, P.M., and Schneiderman, N. (1989). New Signal Processing Techniques for Improved Precision of Noninvasive Impedance Cardiography. Annals of Biomedical Engineering, Vol. 17, pp. 517-534
  22. Laperriere, A.R., VanDercar, D.H., Shyu, L.Y., Ward, M.F., McCabe, P.M., Perry, A.C., Mosher, P.E., and Schneiderman, N. (1989). Microcomputer Servo-controlled Bicycle Ergometer System for  Psychophysiological Research. Psychophysiology, Vol. 26, pp. 201-207.
  23. Reddy, S.P., Shyu, L.Y., Nagel, J., and Schneiderman, N. (1988). Improved Signal Processing Techniques for the determination of Cardiac Parameters Using Thoracic Bioimpedance. Proceedings of the World Congress Medical Physics and Biomedical Engineering, Physics in Medicine & Biology, Vol. 33, pp. 385.
研討會
  1. Du, Y. C., Hu,W. C., Shyu, L. Y., (2004) The Effect of Data Reduction by Independent Component Analysis and Principal Component Analysis in Hand Motion Identification. Proceedings of the 26th Annual International Conference of the IEEE Engineering in Medicine & Biology Society.
  2. Wu, P.C., Tu, Y.C. and Shyu, L.Y., (2002) Development of a Portable Real-Time Heart Rate Variability Monitoring System. Proceedings of Conference of Biomedical Engineering Technology, pp. D1 17-20.
  3. Chen, J.Y., Tain, R.W. and Shyu, L.Y., (2001) Multi-electrode Hand Motion Identification System. Proceedings of Conference of Biomedical Engineering Technology, pp. 475-478.
  4. Tain, R.W., Chen, J.Y. and Shyu, L.Y., (2001) EMG Classification using Artificial Neural Network Implement on FPGA. Proceedings of Conference on Biomedical Engineering Technology, pp. 479-480.
  5. Wu, Y.H. and Shyu, L.Y., (1999) Detection of VPC Using Wavelet Transform and Fuzzy Neural Network. Proceedings of the First Joint BMES/EMBS Conference.
  6. Yang, M. Y., Hu, W. C., and Shyu, L. Y. (1997). ECG Events Detection and Classification Using Wavelet and Neural Networks. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine & Biology Society.
  7. Hu, W. C., Shyu, L. Y., Su, J. L., and Tung, C. S., (1997). Animal 
    Behavioral Monitor for Schedule-Induced Polydipsia Experimental Model. 
    Proceedings of the Annual International Conference of the IEEE Engineering in Medicine & Biology Society.
  8. Chiang, C. Y., Hu, W. C., and Shyu, L. Y. (1997). Portable Impedance 
    Cardiography System for Real-Time Noninvasive Cardiac Output Measurement. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine & Biology Society.
  9. Shyu, L. Y., Huang, C. F., Wu, Y. S., Hu, W. C., and Chao, K. C. (1996). 
    The Use of Thracic-Abdominal Transfer Function in Extracting Fetal 
    Electrocardiogram. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine & Biology Society
  10. Hu, W. C., Su, J. L., Shyu, L. Y., Pan, J. L., and Wang, S. P. (1996). 
    Assessment of Left Ventricular Myocardium Functional Index Using ECG Gated MRI Images. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine & Biology Society
  11. Hurwitz, B.E., Shyu, L.Y., Lu. C.C., Reddy, S.P., Schneiderman, N., and 
    Nagel, J.H. (1991). Influence ofSignal Fidelity on Impedance 
    Cardiographically-derived Values at Resting And Accelerated Heart 
    Rates. Proceedings of the Annual International Conference of the IEEE 
    Engineering in Medicine & Biology Society, pp. 793-794.
  12. Hurwitz, B.E., Shyu, L.Y., Reddy, S.P., Schneiderman, N., and Nagel, J.H. (1990). Coherent Ensemble Averaging Techniques for Impedance 
    Cardiography. Proceedings of the Third Annual IEEE Symposium on 
    Computer-based Medical Systems, IEEE Computer Society Press, Washington, pp. 228-235.
  13. Shyu, L.Y., Reddy, S.P., Nagel, J.H., and Schneiderman, N. (1988). New 
    Signal Processing Techniques for Improved Reliability of Impedance 
    Cardiography. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine & Biology Society, pp. 41-42.
  14. Reddy, S.P., Shyu, L.Y., Hurwitz, B.E., Nagel, J.H., and Schneiderman, N. (1988). Improved Reliability of Impedance Cardiography by New Signal Processing Techniques. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine & Biology Society, pp. 43-44
  15. VanDercar, D.H, Laperriere, A.R., Shyu, L.Y., Ward, M.F., McCabe, P.M., 
    Perry, A. and Schneiderman, N. (1988). Microcomputer Automated System for Measuring Systolic Time Intervals in Response to Exercise and a Phychophysiological Task. Psychophysiology, Vol. 26, pp. 703-711.